0x32 set cc mode transient current and timing, 0x33 read cc mode transient parameters, 0x34 set cv mode transient voltage and timing – B&K Precision 8500-8526 - Manual User Manual

Page 59

Advertising
background image

Byte

offset

Meaning

5

Upper low byte of resistance.

6

Upper high byte of resistance.

7-24

Reserved

0x32 Set CC mode transient current and timing

Byte

offset

Meaning

3 to 6

Value A of current in units of 0.1 mA. Little-endian 4 byte number.

7 to 8

Time for A current in units of 0.1 ms. Little-endian 2 byte number.

9 to 12

Value B of current in units of 0.1 mA. Little-endian 4 byte number.

13 to 14 Time for B current in units of 0.1 ms. Little-endian 2 byte number.

15

Transient operation:

0 is CONTINUOUS
1 is PULSE
2 is TOGGLED

16-24

Reserved

0x33 Read CC mode transient parameters

Byte

offset

Meaning

3 to 6

Value A of current in units of 0.1 mA. Little-endian 4 byte number.

7 to 8

Time for A current in units of 0.1 ms. Little-endian 2 byte number.

9 to 12

Value B of current in units of 0.1 mA. Little-endian 4 byte number.

13 to 14 Time for B current in units of 0.1 ms. Little-endian 2 byte number.

15

Transient operation:

0 is CONTINUOUS
1 is PULSE
2 is TOGGLED

16-24

Reserved

0x34 Set CV mode transient voltage and timing

Byte

offset

Meaning

3 to 6

Value A of voltage in units of 1 mV. Little-endian 4 byte number.

7 to 8

Time for A voltage in units of 0.1 ms. Little-endian 2 byte number.

9 to 12

Value B of voltage in units of 1 mV. Little-endian 4 byte number.

13 to 14 Time for B voltage in units of 0.1 ms. Little-endian 2 byte number.

15

Transient operation:

8500 DC Load Series