6-2-5-2. Connection ezDispatch server setup

The ezDispatch can allocate all the notifications from the following events automatically to the standby

CMS (FreeView Pro ) to dispatch the CMS loading when there are more than 2 CMS server on the

controller center. The ezDispatch program will arrange live video to CMS server to balance the loading

of CMS. Such as there are 5 pcs CMS servers for remote monitoring NVRs, there 13 NVRs send the

Live video to the CMS servers. The ezDispatch preprogram will average all live videos to 5 pcs CMS

servers to get the balance loading for each CMS server. The ezDispatch can be installed and enabled in

one of CMS or any kinds of PC stations. Please refer to for ezDispatch setup.

Follow the steps below to connect ezDispatch Server setup:

Step 1.

Check “Connect to ezDispatch server”.

Step 2.

Type IP address of ezDispatch server #1 where it has been installed and enabled.

Step 3.

Type the port number for connecting ezDispatch server #1. The default port number is

5866”.

Step 4.

Repeat 2~3 to setup for ezDispatch server #2. If the Sever #2 and Server#1 use the same IP

address for Internet access, it should set up the different ports for connecting Server #1 and

Server #2.

Step 5.

Set up the reconnect time to reconnect the server if the network is disconnected.

Step 6.

Click “OK” to save the setting.