3
2
4
5
6
8
10
7
9
11
12
13
16
17
18
14
15
19
20
21
22
23
GB
To access this page from the home page press
and then
.
The following parameters can be set:
Date
1.
Time
2.
Time of inactivity after which the measuring
3.
heads go into standby to reduce battery con-
sumption (infrared LEDs off). The screen saver
is activated. To wake up the measuring heads,
press any key on the keyboard. (option 'OFF' = it
does not occur)
Language
4.
Format of the fractions of an angle
5.
• '/100 (dec) = hundredths of a degree (centesi-
mal degrees)
• °/60 (min) = sixtieth of a degree (sexagesimal
degrees)
Angle resolution shown on the display (the actual
6.
resolution of the instrument does not change)
Toe-in format and resolution
7.
• '/100 °/60 = degrees, resolution specifi ed in
box 6
• mm = millimetres, resolution specifi ed in box 8
• inch (dec) = inches, resolution in tenths of an
inch
• inch (1/4) = inches, resolution in fourths of an
inch
• inch (1/64) = inches, resolution in sixty-fourths
of an inch
Toe-in resolution if expressed in millimetres or
8.
inches
Distance unit of measure
9.
Type of communication between the measuring
10.
heads and the computer ('Cable' = via cable) 'BT'
= Bluetooth; 'BT2' = Second generation Blueto-
oth)
Type of runout permitted ('UP/DOWN' = both
11.
lifted and on the ground; 'UP' = lifted only;
'Bypass' = runout execution not required)
Enables checks on correct runout execution
12.
Help texts:
13.
• Fx: displays on the screen buttons the related
F1,...,F7 keyboard button.
• Help: displays on the screen buttons their
name
• ALL: displays the previous and pages titles
Keyboard language
14.
Settings page password ('ON' = password required
15.
to access the Settings page)
Number of alignments executed
16.
Car database active
17.
Truck database active
18.
COM port setting
19.
do not change (reserved
for technical service).
In IBRIDA or HYBRID mode (
20.
*
): measurements
made with all the sensors (8 sensors) or disabling
the rear toe-in sensors (6 sensors). This second
setting is useful in order to be able to make a
measurement also if the rear toe-in radius is
interrupted.
*
The measurement execution mode
requires the use of 2 CAR sensors and 2 TRUCK
sensors.
For the truck procedure only: level sensor tole-
21.
rance. Select the 'Normal' setting to optimise
measurement accuracy. Use the 'Wide' setting
only if you have diffi culty keeping the measuring
heads level, for example, when measuring with
the engine on
22. Option to disable caster measurement:
ON: steering required
OFF: steering not required
23. Automatic next page for the brake pedal lock
and steering lock positioning pages
AUTO ON: the next page is automatically displa-
yed after 15 seconds
AUTO OFF: you need to press F6 to go to the
next page