Specifications

Pearleye Technical Manual V2.3.0

16

Pearleye P-030 LWIR

Note

The warranty becomes void in case of unauthorized tampering
or any modifications not approved by Allied Vision Technolo-
gies.

Caution

Surge

To avoid damage caused by surge, connect the camera to an
AC/DC power supply. Use a certified industrial power supply
that complies with common industrial standards. Make sure
the polarization of the power supply is correct.

During the camera start-up, inrush currents ≥ 4 A can occur for
20 ms. Use a sufficiently dimensioned power supply to avoid
damage to the camera.

For the DC (direct current) signal, use cable lengths < 30 m.
Consider that the voltage drop increases with the cable length.

AVT (or your local dealer) provides suitable power supplies:

http://www.alliedvisiontec.com/emea/products/
accessories.html

Feature

Specification

Sensor

Amorphous silicon uncooled microbolometer focal plane array (FPA)
ULIS UL 04 17 1; built-in electromechanical shutter

Effective chip size

16 mm (H) x 12 mm (V)

Cell size

25 μm x 25 μm

Resolution (max.)

640 (H) x 480 (V)

Lens mount

M65 x 0.5

Field of view (FOV)

With 18 mm lens: 47.9° x 36.9°

Focus range

0.5 m to infinity (manually adjustable)

Spectral response

8 μm to 14 μm (LWIR)

Pixel format

Mono14

Frame rate

up to 24 fps

Measurement temperature
range

-20 °C to +80 °C (standard version)

Sensitivity (NETD)

typical

80 mK @ 303 K @ f/1.0

Table 4: Specification Pearleye P-030 LWIR