Camera interfaces

Pearleye Technical Manual V2.3.0

27

The current (1) which flows through the optocoupler and the integrated drop-
ping resistor should be > 5 mA and should not exceed 20 mA.

Pearleye P-007 LWIR

For continuous periodical trigger the pulse must be at least 100 μs in length and
the periodic time must be exactly 24.96 ms ± 10 μs.

Pearleye P-030 LWIR

For continuous periodical trigger the pulse must be at least 82 μs in length and
the periodic time must be exactly 41.608 ms ± 20 μs.

Sensor temperature too low (pin 12, 13)

As long as the sensor operating temperature is too low, the sensor control out-
put at pin 12/13 remains active (transistor switched on). After the warm-up
period of the camera this output becomes inactive.

Figure 4: Trigger input diagram

Figure 5: Sensor temperature too low

Caution

Pearleye P-007 LWIR / Pearleye P-030 LWIR: The current that
flows through the optocoupler should not exceed 20 mA (at 12
V, resistance of the optocoupler: R

v

 600 ).