28

An indication of sensor temperature being too low results in a degradation of
image quality and inexact temperature measurement. If this control output
does not become inactive after some minutes of operation, the ambient air tem-
perature of the camera might be too low.

To resolve this, heat up the camera temperature above approx. 15 °C (Pearleye
P-030 LWIR
) or 25 °C (Pearleye P-007 LWIR). Use for e.g. a temperature-
controlled air-flow housing.

Sensor temperature too high (pin 14)

An indication of sensor temperature being too high results in a degradation of
image quality and inexact temperature measurement.

If this control output is permanently active already after some minutes of oper-
ation, the environment temperature of the camera might be too high. A suffi-
cient cooling of the camera is obligatory.

Pearleye P-007 LWIR

For ideal results the camera housing temperature should be lower than 45°C.

Pearleye P-030 LWIR

For ideal results the camera housing temperature should be lower than 35°C.

Frame-sync output (pin 15)

Voltage

Logical Level

Description

≤ 0.8 V

low

Sensor temperature too high

> 4.0 V

high

Normal operation

Table 8: Sensor temperature too high