Technical data – Burkert Type 1094 User Manual

Page 12

Advertising
background image

12

Technical Data

6.

TEchnical daTa

Operating conditions

6.1.

Warning!

danger of explosion!
The controller Type 1094 EV has a protection class of IP00 and is
not designed for use in the explosion-protected area. If it is used
in the area of tank installations, a short-circuit in the controller
could cause an explosion.

If it used in the area of a tank installation, the controller Type

1094 EV must be installed in a control cabinet with an appropri-

ate protection class.

Permitted ambient temperature: -25 – +55 °C

(icing over not permitted)

Permitted air humidity:

5 – 85 %
(condensation not permitted)

noTE!

damage to device caused by icy or wet conditions!
Icy and wet conditions may damage the device and cause
malfunctions.

Protect device from icy and wet conditions caused by dew, etc.

Protection class:

IP00, the electronics are designed for oper-
ation in the control cabinet only.

conformity with the following

6.2.

standards

CE mark compliant with

EMC generic emission standard
IEC-61000-6-1
IEC-61000-6-2
IEC-61000-6-3
IEC-61000-6-4

BImSchV

Bundes-Immissionsschutz-Verordnung
(Federal Emission Protection Ordinance)

21. BImSchV; Ordinance on the Restriction of
Hydrocarbon Emissions during the Refueling of
Vehicles

general Technical data

6.3.

Housing:

Open housing for installation on mounting rail in
accordance with DIN EN 50022 / DIN EN 50035 /
DIN EN 50045

Dimensions:

68 x 76 x 35 mm

Order number:

208373

English

Type 1094 EV

Advertising