Adjustment and operation of the controller – Burkert Type 1094 User Manual

Page 23

Advertising
background image

23

Operation and function

adjustment and operation of the

8.4.

controller

To adjust the controller in a gasoline pump, all components, signal
lines and the gas meter from the calibration case must be connected
correctly.

side selection
Each side of the gasoline pump can be controlled separately via the
slide switch (side selection).

Side 1

Side 2

The appropriate side of the gasoline pump is
controlled by pushing the switch up or down.

Selecting the side of the gasoline pump

Fig. 11:

suB-d plug
(connection to the manual control unit type Mkne-1094)
The controller is operated and calibrated exclusively via the external
manual control unit Type MKNE-1094 which is connected to the con-
troller via a 9-pole SUB-D plug.

Configuration of the SUB-D plug:

pin

i/O

description

1

nc

2

OUT

Clock for serial communication

3

BIDIR

Data line

4

nc

5

PWR

GND

6

nc

7

PWR

+5 V

8

nc

9

nc

Configuration of the SUB-D plug

Table 4:

English

Type 1094 EV