Operation and function

Legend to

Fig. 9:

position description

display function

1

LEDs for side 1:
LED red

Diagnosis display side 1

LED yellow

Switching output motor contactor
side 1

2

LED green

Operating voltage display

3

LEDs for side 2:
LED red

Diagnosis display side 2

LED yellow

Switching output motor contactor
side 2

4

LED red

Without display function

Table 2: LED display functions

The red LED (4) without display function may flicker under
certain operating conditions. However, this has no effect on
the function of the entire controller.

display function side lEds

8.2.1.

The yellow LED (

Table 2: / Pos.1, 3) indicates that the switching output

was activated for the motor contactor of the respective side.
The red LED (

Table 2: / Pos.1, 3) indicates a diagnosis for the outputs

of the respective side.
There are different statuses which will be explained in the following
Troubleshooting chapter.

Troubleshooting

8.2.2.

Troubleshooting is via the red LEDs for side 1 and side 2. Both LEDs
indicate the operating status of the respective side.
The following table describes the different statuses and their meaning
for troubleshooting.

status

description

Quickly flashing
LED

The valve is operating; everything is working
correctly.

Slowly flashing LED

There is no fueling in progress; everything is
working correctly.

LED permanently on
or off

The electronics are defective.

1 pulses every 3 s

The electronics are not calibrated.

2 pulses every 3 s

The valve current is too low.

(3

This means

that the valve is not connected.