Installation

insTallaTiOn

7.

important documents

7.1.

To connect the individual gasoline pump components to
the controller Type 1094 EV, you will require the particular
interface conditions such as level, clock rates, resistors, cur-
rents, etc. These can be found on the data sheets and/or in
the operating instructions for the individual components.
all the documentation for the gasoline pump is
available from the supplier or manufacturer of the
gasoline pump.

Provide the following documents for start-up of the controller:

Operating instructions for the piston meter/gasoline pump

computer
Operating instructions for the proportional valve Type 2832, 2832EV,

6022 from Bürkert
Operating instructions for the vacuum pump - required for adjustment

of the correction factor
Operating instructions for the manual control unit Type MKNE-1094

from Bürkert

installation

7.2.

safety instructions

7.2.1.

DangEr!

risk of injury due to electrical shock!

Before reaching into the device or the equipment, switch off the

power supply and secure to prevent reactivation!
Observe applicable accident prevention and safety regulations

for electrical equipment!

Warning!

risk of injury from improper installation!

Installation may be carried out by authorized technicians only

and with the appropriate tools!

danger of explosion!

If it used in the area of a tank installation, the controller Type

1094 EV must be installed in a control cabinet with an appropri-

ate protection class.

To install the controller in the control cabinet, the housing can be
installed directly on a mounting rail.