Burkert Type 8681 User Manual

Page 3

Advertising
background image

8

NOTE!

Electrostatic sensitive components / modules!

The device contains electronic components, which react

sensitively to electrostatic discharge (ESD). Contact
with electrostatically charged persons or objects may
be hazardous to these components. In the worst case
scenario, they will be destroyed immediately or will fail
after start-up.

Observe the requirements in accordance with DIN EN

61340-5-1 and 5-2 to minimize or avoid the possibility of
damage caused by sudden electrostatic discharge!

Also, ensure that you do not touch electronic components

when the power supply voltage is present!

Control Head Type 8681 was developed with due
consideration given to accepted safety rules and
is state-of-the-art. Nevertheless, dangerous situa-
tions may occur.

Failure to observe this operating manual and its oper-
ating instructions as well as unauthorized tampering with
the device release us from any liability and also invalidate
the warranty covering the devices and accessories!

english

9

Explosive Atmosphere

4.1.

NOTE!

Operation of the Control Head in Explosive
Atmosphere

The housing may not be opened when devices are

charged! It should be secured against unintentional
opening using plastic self-cutting screws or seal (or
comparable)!

Layers of dust on the housing may not exceed 5 mm!

Lint, conductive and non-conductive dust particles are
allowed.
The inside of the housing may not be dirty!

Activating the DIP switches on the circuit board, using

the service plug and the Teach buttons is not allowed in
explosive atmosphere!

english

10

GENERAL INFORMATION

5.

Scope of Supply

5.1.

Check immediately upon receipt of the delivery that the con-
tents are not damaged and that the type and scope agree
with the delivery note and packing list.

If there are any discrepancies, please contact us immedi-
ately.

Contact address

5.2.

Germany:
Bürkert Fluid Control Systems
Sales Center
Christian-Bürkert-Straße 13-17
D-74653 Ingelfi ngen

Tel.:

+49 7940 10 91 111

Fax:

+49 7940 10 91 448

E-mail:

[email protected]

International:

The contact addresses can be found on the Internet at:

www.burkert.com

Bürkert

Company

Locations

english

11

STRUCTURE AND FUNCTION

6.

The Control Head Type 8681 has been designed for use
as actuation of pneumatically operated process valves and/
or for recording the switching states of these.

For the recording and feedback of the process valve
switching positions to a higher-level control, the control
head has been equipped with a contactless position mea-
suring system, which works with three discrete, adjustable
feedback signals (Teach-In Function).

Various pneumatic and electrical connection variants are
available.

Positions and status information can be indicated by means
of three signal colors.

Manual Control

6.1.

Standardly, the control head provides the following:

a magnetic manual control that is easily accessible from

the outside on the basis of encoded magnetic fi elds for
Solenoid Valve 1 (Connection 2/A1), as well as

a mechanical manual control accessible when the hood

is open on each equipped solenoid valve.

english

Type 8681

Advertising