Step 2 – ADC Campus-REX2 RS User Manual

Page 114

Advertising
background image

Chapter 7 - Using the LCD for Configuration and Management

102

Campus-REX2 RS Interface Card User Manual

2

To select the transceiver mode:

a

Press Next until

XCVR Mode

is displayed.

b

Press Enter.

c

Press Next until your choice is displayed:

Master

initiates the HDSL link. The other Campus unit must

be set to Slave or Auto.

Slave

waits for the other Campus unit to initiate the HDSL

link. The other unit must be set to Master or Auto.

Auto

(default) automatically switches between Master and

Slave until an HDSL link is established.

The Transceiver Mode option determines the hierarchy of the two
Campus units when attempting to establish an HDSL link.

d

Press Enter.

3

To configure

LOOP MODE

, do the following:

a

Press Next to display

LOOP MODE

.

b

Press Enter.

c

Press Next to change the setting from 1 Loop (default) to 2 Loop,
then press Enter. The LCD displays

LOOP MODE=2 Loops

.

4

To configure

HDSL RATE

, do the following:

a

Press Next to display

HDSL RATE

.

b

Press Enter.

It is recommended that you leave the Transceiver Mode
option set to Auto unless you require that a particular end of
the HDSL connection be the Master or Slave.

Also, this value cannot be changed if the HDSL link is up.

Advertising