Chapter 5 - Monitoring and Testing the Campus System

Campus-REX2 RS Interface Card User Manual

79

Viewing Local Alarm History

This screen displays alarm history information. From the System Status
Menu, type

then press

. The Local Alarm History screen is

displayed.

This screen shows alarm history of the local unit. If the HDSL line uses two
loops, the screen includes information for both loops. The screen includes
information on the following alarms:

Errored seconds (ES) for HDSL loop A (first pair) and HDSL loop B
(second pair, when applicable)

Margin for HDSL loop A (first pair) and HDSL loop B (second pair,
when applicable)

Loss of Signal (LOS) for the HDSL port

To view remote alarm history, type

then press

.

To update the information, type

then press

.

To clear the information, type

then press

.

Alarm history information is lost when power is removed from
the Campus unit.

4

ENTER

Jul 07, 2003

ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 08:19:34

Local Unit ID:

Local I/F:

REX2

Remote Unit ID: Inactive

Remote I/F: Inactive

Circuit ID:

LOCAL ALARM HISTORY

Type

Current

First

Last

Count

HDSL Link,

ACTIVE

Dec 09, 1999-04:30:03

Nov 31, 1999-12:21:01

1

ES,

HDSL-A

OFF

0

ES,

HDSL-B

OFF

0

Margin, HDSL-A

OFF

0

Margin, HDSL-B

OFF

0

LOS,

Port

OFF

0

Last Cleared:

None

(S)witch to Remote Alarm History

(U)pdate

(C)lear

(R)eturn

(M)ain Menu

ENTER CHOICE>