Setting hdsl alarms – ADC Campus-REX2 RS User Manual

Page 39

Advertising
background image

Chapter 2 - Configuring HDSL Parameters

Campus-REX2 RS Interface Card User Manual

27

2

From the System Settings Menu, type

then press

. The System

Parameters screen is displayed.

Setting HDSL Alarms

The default setting for all alarming is Disabled. Completing the following
steps to either select a value or to enable the alarm reporting.

1

To select an HDSL ES Alarm Threshold (Disabled is the default), type

then press

to select one of the following as the ES threshold:

17 errored seconds occurring in a 24-hour period

170 errored seconds occurring in a 24-hour period

An alarm is generated when the defined threshold for HDSL errored
seconds is exceeded, indicating a deterioration in performance. An
errored second is one in which one or more block errors (CRC
anomalies) or LOSW defects occur within the threshold interval.

2

To configure the HDSL Margin Alarm Threshold:

a

Type then

press

.

b

At the prompt, enter a value between 1 and 25 decibels (dB) then
press

.

Enter Margin alarm threshold value (1-25dB), or "D"

to disable>6

An alarm is generated when the defined threshold for HDSL Margin is
exceeded. Margin indicates the signal to noise ratio at a receiver point.

1

ENTER

Jul 07, 2003

ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 08:19:34

Local Unit ID:

Local I/F:

REX2

Remote Unit ID:

Remote I/F: REX2

Circuit ID:

SYSTEM PARAMETERS

1) CHANGE SYSTEM TIME

2) CHANGE SYSTEM DATE

3) CHANGE UNIT ID

4) CHANGE CIRCUIT ID

5) CHANGE UNIT PASSWORD

6) HDSL ES Alarm Threshold:

Disabled

(Disabled, 17, 170)

7) HDSL Margin Alarm Threshold:

Disabled

8) Local Data Port LOS Alarm:

Disabled

(Disabled, Enabled)

9) Remote Data Port LOS Alarm:

Disabled

(Disabled, Enabled)

10) RESTORE FACTORY DEFAULTS

(R)eturn

(M)ain Menu

ENTER CHOICE>

6

ENTER

7

ENTER

ENTER

Advertising