20

Chapter 3: Settng up the Printer

A776 Two-Color Thermal/Impact Hybrid Printer: User Guide

A776 UG00001 B 10/06

Sample diagnostic menu and print test for a printer with a serial connection. Ethernet diagnostic printout not shown.

Ethernet parameters can not be changed in the configuration menu.

Paper type can be changed in the configuration menu.

Paper types and grades available:

Type 0 - Monochrome grades

Kanzaki P-310

Type 1 - Two-color grades

Kanzaki P-310 RB

Type 4 - Two-color grades

Kanzaki P-320 BB

Type 5 - Two-color grades

Kanzaki P-320 RB

See the Programming Guide for more information.

Test Printout without imaging

A776 / B789 Diagnostics Form without Imager

*** A776 / B780 – Diagnostics Form ***

Model number

: A776-0000

Serial number

: 0000000000

Boot Firmware
Revision

: V1.05

CRC

: 1A0E

P/N

: 189-7760246A

Flash Firmware
Revision

: V1.03

CRC

: ADCC

P/N

: 189-7760248A

H/W parameters
Flash Memoriy Size

: 2 Mbytes

Flash Logos/Fonts

: 1024 kbytes

Flash User Storage

: 64 kbytes

Flash Journal Size

: 64 kbytes

SRAM Size

: 512 kbytes

Head setting

: D

Paper Type setting

: Type 0, Monochrome

Color Density Adj

: n/a

Print Density (Mono)

: 100%

Max Speed

: 180 mm/sec

Max Power

: 55 W

Paper Low Sensor

: Enabled

MICR

: Enabled

MICR Dual Pass

: Disabled

MICR DC offset

: 80

Check Flip

: Disabled

Slip Normal Alignment

: 0Dh/13d

Compressed Alignment : 0Ch/12d

Comm. Interface
RX Buffer Size

: 4096

Interface type

: RS232/USB

Parameters
Baud Rate

: 115200

Data Bits

: 8

Stop Bit

: 1

Parity

: NONE

Flow Control

: DTR/DSR

Reception Errors

: Ignore

USB Driver Type

: RS232 Emulation

Resident Code Pages

: 437, 850, 852. 858

860, 863, 865, 866

1252, 862, 737

Logo(s) defined

: NO

User Char(s) defined

: NO

Journal Unused

: 64 kbytes

To enter Printer Config Menu :
1) Flip DIP switch #1 down
2) Reset the printer, while holding
the Paper Feed button down