Digital inputs, System, Outputs – CONTREX CXB2040 User Manual

Page 14: 2 mechanical

Advertising
background image

8900 Zachary Lane N., Maple Grove, MN 55369 U.S.A.

11

1.3.2 Mechanical

1.3.1.3 Digital Inputs:

 +/-Limit, Inhibit & Reset:

40/-0.5V max. Terminated by 10,000S.

 Fault (as input):

40/-0.5V max. Terminated by 10,000S.

 Typical for all digital inputs: Digital inputs have hysteresis with thresholds

at 1/3 and and 2/3 of +5V or +15V depending on

range

select

jumper.

1.3.1.4 System:

 Drift offset over temperature reference to input:

0.01mV/

o

C max.

 Frequency response (Velocity loop):

750Hz min.

 Frequency response (Current loop):

2KHz min.

 Dead band:

None.

 Form factor:

1.01.

1.3.1.5 Outputs:

Fault (as output):

Active low. Open-collector output can sink 500mA max.

Absolute motor current(J1-3):

10A/V.

Tachometer :

1000S source impedance, a high input impedance meter must

be used (1M S /volt). Maximum Tachometer output voltage

for 12 bit = 1.5V/KRPM, 14 bit = 2V/KRPM.

Encoder outputs:

Standard TTL levels with 20mA sink or source capability.

(SMA8215)

CHAPTER 1: DESCRIPTION, FEATURES AND SPECIFICATIONS

Model

L x W x H

(inches)

Weight

(lbs)

CXB1525 (Stand Alone Amplifier)

9.025 x 4.00 x 4.96

5.25

CXB2040 (Stand Alone Amplifier)

9.025 x 4.00 x 4.96

5.25

Advertising
This manual is related to the following products: