4.3.2 Wire Size and Type:

IMPORTANT: To ensure safe operation, CONTREX strongly recommends that all wiring conform

to all local and national codes.

RECOMMENDED WIRE SIZE and TYPE:

MOTOR WIRES:

14AWG, shielded - STANDARD.

12AWG,

shielded

-

HIGH

POWER.

MOTOR CASE GND:

Same as motor wires, or use metallic conduit.

MAIN POWER:

Same as motor wires.

SIGNAL INPUT:

22AWG, twisted-pair, shielded.

LOGIC INPUTS/OUTPUTS:

22AWG, shielded with its return lead.

EXTERNAL TACHOMETER:

22AWG, twisted-pair, shielded.

RESOLVER OUTPUTS and

EXCITATION

:

22AWG,

three

twisted-pairs, over-all shielded.

4.3.3 Connector Size and Type:

4.3.3.1 The Power and Motor Connector of the Stand Alone Amplifier:



Motor - J2 of the Stand Alone Amplifier:

Mating Connector: PHOENIX CONTACT, COMBICON Plugs in 7.62mm

Pitch

(P/N: GMVSTBR 2.5/3-ST-7.62):

- with vertical plug-in direction to the conductor axis.

- 3 positions.

- Color: green.



Power Input - J6 of the Stand Alone Amplifier:

Mating Connector: PHOENIX CONTACT, COMBICON Plugs in 7.62mm

Pitch

(P/N: GMVSTBW 2.5/4-ST-7.62):

- with vertical plug-in direction to the conductor axis.

- 4 positions.

- Color: green.