3 encoder ooutput resolution configuration – CONTREX CXB2040 User Manual

Page 31

Advertising
background image

CXB1525 and CXB2040 MANUAL

8900 Zachary Lane N., Maple Grove, MN 55369 U.S.A.

28

Resolution

PLD

CODE

PLD PART

NUMBER

S1-1

S1-2

BITS
MIN.

125

000

8000-1212

ON

ON

10

128

000

8000-1212

ON

OFF

10

250

000

8000-1212

OFF

ON

10

256

000

8000-1212

OFF

OFF

10

500

001

8000-1213

ON

ON

12

512

001

8000-1213

ON

OFF

12

1000

001

8000-1213

OFF

ON

12

1024

001

8000-1213

OFF

OFF

12

2000

010

8000-1214

ON

ON

14

2048

010

8000-1214

ON

OFF

14

4000

010

8000-1214

OFF

ON

14

4096

010

8000-1214

OFF

OFF

14

360

011

8000-1218

ON

ON

12

720

011

8000-1218

ON

OFF

12

2160

011

8000-1218

OFF

ON

14

3600

011

8000-1218

OFF

OFF

14

625

100

8000-1215

ON

ON

12

1250

101

8000-1216

ON

ON

14

2500

110

8000-1217

ON

ON

14

5.3.3 Encoder Output Resolution Configuration:

Refer to Appendix B drawing 8000-1430 and 8000-1431. There are nineteen standard resolutions.

Up to four resolutions are contained in a single PLD. To configure the pre-amp for a given resolution,

ensure that you have the correct PLD (U13) and then configure the dip-switches S1-1 and S1-2 as shown

below.

The BITS refer to the Resolver-to-Digital resolution which must be factory configured. Encoder

resolution may be changed at any time to a resolution which requires the same or fewer bits. Increasing

the bits increases the possible encoder resolution, but decreases the maximum motor RPM (refer to

Section 5.3.5).