2 under voltage fault, 3 motor over temp fault – CONTREX CXB2040 User Manual

Page 41

Advertising
background image

CXB1525 and CXB2040 MANUAL

8900 Zachary Lane N., Maple Grove, MN 55369 U.S.A.

38

7.2.2 Under-Voltage Fault:

When the +15VDC is below +12VDC, a level that would cause unreliable operation, the Run LED

will turn off, a Fault Output is generated, and the amplifier is inhibited. This is not a latched condition:

that is, if the problem is resolved the amplifier will resume operation.

The following is a list of possible causes:

1. Main AC line voltage is too low.

2. Bad

rectifier

bridge.

3. Bad DC buss filter capacitor.

7.2.3 Motor Over-Temp Fault:

When the motor temperature has reached a level that, if exceeded, would damage the motor, the Run

LED will turn off, the OVER TEMP LED will turn on and a Fault Output is generated, and the amplifier

is inhibited.

The following is a list of possible causes:

1. The continuous motor current is too high.

2. Binding or stalling of motor shaft due to excessive mechanical overload.

3. Motor rating too small for the load.

7.2.4 High-Speed Electronic Circuit Breaker (HS/ECB) Fault:

When the peak output of the amplifier exceeds 80A for 10 micro-seconds, the Run LED will turn off,

the HS/ECB LED's are latched on, a Fault Output is generated, and the amplifier is inhibited.

The following is a list of possible causes:

1. Shorted

motor

leads.

2. Motor inductance too low.

3. Short from a motor lead to ground.

7.2.5 Low-Speed Electronic Circuit Breaker (LS/ECB) Fault:

When the RMS output of the amplifier exceeds the current set to protect the motor and or the

maximum setting of the amplifier for 3 seconds, the Run LED will turn off, the LS/ECB LED's are

latched on, a Fault Output is generated, and the amplifier is inhibited. Refer to section 1.3.1.1 for the

amplifier rms settings.

The following is a list of possible causes:

1. Binding or stalling of motor shaft due to excessive mechanical overload.

2. Overload of amplifier output to motor.

3. Large reflected load inertia.

Advertising
This manual is related to the following products: