CHAPTER SEVEN: MAINTENANCE, REPAIR, and WARRANTY

7.1 MAINTENANCE:

Contrex amplifiers do not require any scheduled maintenance, although it is a good idea to

occasionally check for dust build-up or other contamination.

7.2 AMPLIFIER FAULTS:

If an amplifier should cease to operate and one or more of the fault LED's are lit, review the sections

which follow on the fault in question for information and possible causes.

A FAULT CAN ONLY BE CAUSED BY ABNORMAL CONDITIONS. LOCATE AND

CORRECT THE CAUSE OF THE FAULT BEFORE REPEATED RECYCLING OF POWER TO

THE AMPLIFIER TO PREVENT POSSIBLE DAMAGE.

7.2.1 Table of Fault LED Conditions:

INPUT OR FAULT
CONDITION

RUN

LED

HS/ECB

LED

LS/ECB

LED

OVER VOLT

LED

OVER TEMP

LED

FAULT

OUTPUT

NORMAL
OPERATION

ON

OFF

OFF

OFF

OFF

NO

LIMIT + (ON)

ON

OFF

OFF

OFF

OFF

NO

LIMIT - (ON)

ON

OFF

OFF

OFF

OFF

NO

INHIBIT (ON)

OFF

ON

OFF

OFF

OFF

NO

RESET IN (ON)

OFF

OFF

OFF

OFF

OFF

NO

EXT. FAULT (ON)

OFF

OFF

OFF

OFF

OFF

YES

UNDER-VOLTAGE
(+15V)

OFF

OFF

OFF

OFF

OFF

YES

HS/ECB (LATCHED)

OFF

ON

OFF

OFF

OFF

YES

LS/ECB (LATCHED)

OFF

OFF

ON

OFF

OFF

YES

OVER-VOLTAGE B+
(LATCHED)

OFF

OFF

OFF

ON

OFF

YES

OVER TEMP
(LATCHED)

OFF

OFF

OFF

OFF

ON

YES

CHAPTER 7: MAINTENANCE, REPAIR, and WARRANTY