CHAPTER 5: CONFIGURATION

MOTOR:

S3-1

S3-2

S3-3

S3-4

2 POLE

ON

ON

ON

ON

4 POLE

ON

ON

ON

OFF

6 POLE

ON

ON

OFF

ON

8 POLE

ON

ON

OFF

OFF

10 POLE

ON

OFF

ON

ON

12 POLE

ON

OFF

ON

OFF

ZERO

ON

OFF

OFF

ON

INDEX

ON

OFF

OFF

OFF

5.3.4 Motor Pole Configuration:

Dip-switch S3-1, S3-2, S3-3 and S3-4 configures the pre-amp for the number of poles in the motor.

They are also used to set up certain calibration modes. Refer to the chart below and set the dip switches

for the correct number of poles.

S3-5

S3-6

S3-7

S3-8

MAX

RPM

TACH VOLTS

V/1000 RPM

10 BIT

ON

OFF

ON
ON

ON
ON

ON
ON

62,400
31,200

0.13
0.26

12 BIT

ON

OFF

OFF
OFF

OFF
OFF

ON
ON

15,000

7,800

0.5
1.0

14 BIT

ON

OFF

OFF
OFF

ON
ON

OFF
OFF

3,900
1,950

2.0
4.0

5.3.5 PLD BIT Configuration:

The Tach. Volts (V/1000RPM) are given for the MAX. RPM of the BIT resolution. Consult a

CONTREX applications engineer should you have any questions.