CHAPTER FIVE: CONFIGURATION

5.1 INTRODUCTION:

Each amplifier has several configuration options. This chapter describes these options and how to

implement them. If desired, CONTREX will be happy to pre-configure your amplifiers.

NOTE: Each amplifier module is configured and shipped according to the model number (instructions to

construct a model number is in chapter three) when the order is placed. It is important for the

user to realize that any adjustment on the dip-switches by the user will result in discrepancies

between the model number and the actual configuration of the amplifier.

5.2 LOGIC INPUT CONFIGURATION:

There are five logic inputs: Limit +, Limit -, Inhibit, Reset In, Motor Temp. The first four may be

configured for active-high or active-low signals, and pulled-up or pulled-down termination (type A, B, C,

and D). The motor-temp may be configured for active-high or active-low signals, and is always pulled-up

(type A, and C). All five logic inputs have a selectable 0 to +5VDC or 0 to +15VDC range.

Type "A": Requires grounding of input to disable the amplifier (pull-up, active-low).

Type "B": Requires a positive voltage at input to disable the amplifier (pull-down, active-high).

Type "C": Requires grounding of input to enable the amplifier (pull-up, active-high).

Type "D": Requires a positive voltage at input to enable the amplifier (pull-down, active-low).