Power, Battery, & Ground Wiring

Power Wiring

NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS

COMPLETE. TURN MASTER POWER SWITCH OFF BEFORE WIRING.

1. Route two wires between the AE-500 and the power transformer.

• For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt

insulated wire.

• For power wire runs up to 200 feet, use 16 AWG, THHN 600-volt

insulated wire.

2. Connect the wires to the transformer. Connect the other end of the

wires to the AE-500 AC1 & AC2 terminals.

Backup Battery

Use of battery backup is optional. It will allow the AE-500 to operate for
short periods of time without AC power. The door or gate access device
must use some type of battery backup of its own for the entire system to
be functional.

NOTE: The AE-500 does not supply battery charging current. An

external battery charger will be required to maintain the battery.

A backup battery will not fi t into the AE-500 case. Protect the backup
battery inside a rain-tight NEMA enclosure suitable for the installation.

NOTE: A backup battery is not required to maintain the AE-500

programming memory during power outages.

1. Route two wires between the AE-500 and the backup battery.
2. Connect the battery positive to the DC+ terminal.
3. Connect the battery negative to the DC- terminal.

Earth Ground

For the best ground, use size 12 gauge solid wire or larger to connect
the AE-500 to an 8-foot copper ground rod. Locate the ground rod next
to the Power and Telephone company rods and bond the rods together
with a new clamp. Do not disturb the clamps installed by the Power or
Telephone Company. Alternately, connect to a cold water pipe for the
earth ground.

1. Connect the wire from the earth ground to the AE-500’s CASE

GROUND STUD.

NOTE: The EARTH GROUND terminal is internally connected

to the circuit board ground, which is connected by a green ground
wire to the
EARTH GROUND STUD.

Optional Color CCTV Camera

Linear’s Model CCM-1 (P/N ACP00904) CCTV camera can be installed
inside the AE-500 Entry System. The camera provides a video signal for
viewing the area in front of the entry system. The CAMERA connector is
used to connect the camera to the AE-500. The 4-conductor cable routes
power to, and video from the camera. The VIDEO jack is the camera
output for connection to a video cable with a Type “BNC” connector. Up to
400 feet of 75-ohm RG-59 video cable can be used.

Camera Installation

1. Remove the two locknuts and the cover plate from the camera

mounting studs above the keyswitch on the AE-500 faceplate.

2. Install the protective clear window.
3. Mount the camera assembly on the two studs, with the alignment

hole in the camera bracket towards the top. Secure the camera
with the two locknuts.

4. Connect the camera’s cable to the AE-500’s CAMERA connector.

Connect the video cable to the AE-500’s VIDEO connector.

5. Connect the other end of the video cable to the video system.

16 VAC

20 VA

TRANSFORMER

EARTH

GROUND

STAKE

12 VOLT

BATTERY

POWER

TERMINALS

AC2

AC1

DC -

DC +

EARTH GROUND

EARTH

GROUND

STUD

NOTE: THE OPTIONAL
BACKUP BATTERY
WILL REQUIRE AN
EXTERNAL CHARGER

1

REMOVE PLATE & RETAINING NUTS

2

4

COVER PLATE

INSTALL THE CLEAR WINDOW

REMOVE THE LENS CAP!

ATTACH CAMERA WITH TWO NUTS

HOLE
ON TOP

3

REMOVE PROTECTIVE

BACKING AND APPLY

WINDOW WITH

ADHESIVE SIDE
AGAINST DOOR

CONNECT CAMERA POWER AND VIDEO

VIDEO

CAMERA POWER

Advertising