Entry System Mounting

The AE-500 cabinet is designed to be mounted three ways:

• The unit can be mounted directly to a wall or fl at surface.
• The unit can be mounted recessed into a wall.
• The unit can be mounted on a standard goose-neck pedestal.

Choose a well lit location near the controlled opening. Wiring access for
power, telephone, earth ground, and control output must be available to
the mounting location. If the optional remote keypad or remote antenna
it used, wiring access for these cables must also be available to the
mounting location.

Static Electricity Warning

The unit’s main circuit board contains static sensitive electronic
components that can be damaged or destroyed by static discharges
during installation. Discharge the static electricity from your body by
touching a grounded object before handling the unit’s circuit board.

Mounting Preparation

Before mounting the system, the main circuit board must be removed to
provide access for the wiring hole and mounting fasteners.

CAUTION!: Touch a grounded object before proceeding to

discharge static electricity from your body.

1. Carefully remove the six main circuit board wiring harness

connectors:

• The 2-pin postal switch connector.
• The 16-pin display connector.
• The 7-pin keypad connector.
• The 8-pin keypad lighting connector.
• The 3-pin speaker connector.
• The 2-pin microphone connector.

2. Remove the six circuit board screws. Note how the green ground

wire lugs are connected with the upper left screw.

3. Carefully remove the circuit board. Hold it by the edges. Set it aside

in a safe place.

Reverse these steps to replace the circuit board after the cabinet
mounting is complete and the system wiring has been routed into the
panel.

Surface Mounting

The cabinet can be mounted on a wall or any suitable fl at surface. The
four 3/8” mounting holes or the four self-drill locations can be used to
attach the cabinet to the surface.

1. For wall mounting, hold the cabinet at the approximate mounting

location where the display will be about eye level or slightly above.

2A. If using the 3/8” mounting holes, mark the four mounting hole

centers. Drill as required. Use the appropriate fasteners for the
mounting surface to secure the cabinet.

2B. If using the self-drill mounting holes, choose the correct size bit for

the fasteners and drill the cabinet as required. Use the appropriate
fasteners for the mounting surface to secure the cabinet.

CAUTION!: After drilling, remove any metal chips from the

inside of the cabinet.

3. After routing the wiring into the cabinet, replace the circuit board

and plug in each wiring connector. Be sure to replace the green
ground wire.

CAREFULLY REMOVE THE
SIX WIRING HARNESS
CONNECTORS

1

2

REMOVE THE SIX
CIRCUIT BOARD
SCREWS

3

CAREFULLY REMOVE THE
CIRCUIT BOARD

MOUNTING

PREPARATION

GROUND WIRE

1

MARK THE FOUR
MOUNTING HOLES

ATTACH THE CABINET WITH APPROPRIATE
HARDWARE FOR THE MOUNTING SURFACE

DRILL THE CABINET AT THE
PRE-MARKED LOCATIONS

2

OR

SURFACE

MOUNTING

Advertising