03#length, 31#code#code#relay#temp, 32#code#relay#temp – Controlled Products Systems Group AE-500 User Manual

Page 18: 33#code#code, Entry code programming

Advertising
background image

18

Entry Code Programming

Changing the Entry Code Length

The factory setting for the entry code length is 4 digits. It can be set to 2-6 digits.

1. If not already in Programming Mode, connect by telephone or use the

local keypad. Enter the master password and access programming.

2. Press

3. Enter the entry code length (2, 3, 4, 5, or 6).
4. Press
5. Exit Programming Mode if all programming is complete.

Adding an Entry Code

1. If not already in Programming Mode, connect by telephone or use the

local keypad. Enter the master password and access programming.

2. Press

3. Enter the entry code.
4. Press
5. Enter the entry code again.
6. Press
7. If access to both relays is OK for this code, and the number of uses is

unlimited, skip to Step 12.

8. Enter the number for the relay output(s) that this entry code will be allowed

to activate or for toggle operation:

• Enter 1 for Relay “A” • Enter 2 for Relay “B” • Enter 3 for Relays “A” & “B”
• Enter 4 to toggle Relay “A” • Enter 5 for to toggle Relay “B”

9. Press
10. If the number of uses is unlimited, skip to Step 12.
11. Enter the number of uses allowed (1-250).
12. Press
13. Exit Programming Mode if all programming is complete.

Modifying an Entry Code

Once entry codes have been set, they can be modifi ed to change the relay(s) to
activate or the number of uses permitted.

1. If not already in Programming Mode, connect by telephone or use the

local keypad. Enter the master password and access programming.

2. Press

3. Enter the entry code.
4. Press
5. Enter the number for the relay output(s) that this entry code will be allowed

to activate or for toggle operation:

• Enter 1 for Relay “A” • Enter 2 for Relay “B” • Enter 3 for Relays “A” & “B”
• Enter 4 to toggle Relay “A” • Enter 5 for to toggle Relay “B”

6. Press
7. If the number of uses is unlimited, skip to Step 9.
8. Enter the number of uses allowed (1-250).
9. Press
10. Exit Programming Mode if all programming is complete.

Deleting an Entry Code

Entry codes can be deleted individually.

1. If not already in Programming Mode, connect by telephone or use the

local keypad. Enter the master password and access programming.

2. Press

3. Enter the entry code to delete.
4. Press
5. Enter the entry code to delete again.
6. Press
7. Exit Programming Mode if all programming is complete.

PPN 03

03#LENGTH#

LENGTH = NUMBER (2-6) OF ENTRY CODE DIGITS

ENTRY CODE LENGTH

FACTORY SETTING: 4 DIGITS

PPN 31

31#CODE#CODE#RELAY#TEMP#

CODE = THE NEW ENTRY CODE
RELAY = 1 FOR RELAY "A"
RELAY = 2 FOR RELAY "B"
RELAY = 3 FOR RELAYS "A" AND "B"
RELAY = 4 TO TOGGLE RELAY "A" (ALTERNATES ON OR OFF)
RELAY = 5 TO TOGGLE RELAY "B" (ALTERNATES ON OR OFF)
TEMP = NUMBER OF USES ALLOWED (1-250)

ADDING AN ENTRY CODE

FACTORY SETTING: RELAYS "A" & "B", UNLIMITED USE

PPN 32

32#CODE#RELAY#TEMP#

CODE = ENTRY CODE TO MODIFY
RELAY = 1 FOR RELAY "A"
RELAY = 2 FOR RELAY "B"
RELAY = 3 FOR RELAYS "A" AND "B"
RELAY = 4 TO TOGGLE RELAY "A" (ALTERNATES ON OR OFF)
RELAY = 5 TO TOGGLE RELAY "B" (ALTERNATES ON OR OFF)
TEMP = NUMBER OF USES ALLOWED (1-250)

MODIFYING AN ENTRY CODE

FACTORY SETTING: RELAYS "A" & "B", UNLIMITED USE

PPN 33

33#CODE#CODE#

CODE = THE ENTRY CODE TO DELETE

DELETING AN ENTRY CODE

An entry code is a number entered at the AE-500 keypad or remote keypad to request
access. Up to 500 entry codes can be set. Entry codes can be from two to six digits in length
(all will be the same length).
Entry codes can be programmed for timed or toggle operation. Timed relays activate for a
programmed length of time. Toggle relays latch on until the next time a toggle entry code is
entered, then the relay unlatches. Each entry code can also be set for a limited or unlimited
number of uses.
An entry code will activate Relay Channel “A” or “B” depending on how the entry code is
programmed and whether or not a remote keypad is attached:

When an entry code is programmed to activate a specifi c relay, the selected relay will
activate when the code is entered on either the AE-500 keypad or the remote keypad.
When an entry code is programmed to activate both relays, and a remote keypad is
attached
, Relay Channel “A” will activate if the entry code is entered on the AE-500 keypad;
Relay Channel “B” will activate if the entry code is entered on the remote keypad.
When an entry code is programmed to activate both relays, and a remote keypad is not
attached
, the entry code will activate both Relay Channels “A” and “B”.

When an entry code is programmed to activate both relays, only timed relay mode is
available for that code, toggle relay mode is unavailable.

Advertising