41#number#fc#id, 42#fc#id, 43#fc#id – Controlled Products Systems Group AE-500 User Manual

Page 19: 45#fc#id, Wireless transmitter programming

Advertising
background image

19

Wireless Transmitter Programming

Up to 500 wireless transmitters can be used with the system. Transmitters can
be ordered in pre-programmed blocks of sequential ID codes. Up to 16 blocks of
transmitters can be used. Transmitter blocks can be ordered with a Facility Code
of 1-15 for block identifi cation if desired. Using Facility Codes is optional. For
security, an individual transmitter can be deactivated in case it is lost or stolen.

NOTE: Transmitters will activate Relay Channels “A” or “B” depending on

the setting of the transmitter button options. See Transmitter Button Setup
(PPN #44) in the System Options section of these instructions.

Assign Block Transmiiter

Assigning a transmitter block assigns memory space for each block of
transmitters used with the AE-500.

NOTE: When a block of transmitters is assigned, all transmitters in the

block will become active and ready to use.

1. If not already in Programming Mode, connect by telephone or use the

local keypad. Enter the master password and access programming.

2. Press

3. Enter the number of transmitters in the block.
4. Press
5. Enter the transmitter block’s facility code.
NOTE: Facility codes are optional. Enter 0 to have the system ignore the

transmitter block’s facility code.

6. Press
7. Enter the fi rst (lowest) transmitter ID number for the block of transmitters.
8. Press
9. Exit Programming Mode if all programming is complete.

Assign Single Enrolled Transmitter

Assigning a transmitter allocates memory space for the transmitter

NOTE: When a transmitter is assigned, it will become active and ready to

use.

1. If not already in Programming Mode, connect by telephone or use the local

keypad. Enter the master password and access programming.

2. Press

3. Enter the transmitter facility code (enter 0 if not used).
4. Press
5. Enter the transmitter ID number of the transmitter
6. Press
7. Exit Programming Mode if all programming is complete.

Suspend a Transmitter

Transmitters may be suspended if necessary (such as when a transmitter is lost
or stolen).

1. If not already in Programming Mode, connect by telephone or use the

local keypad. Enter the master password and access programming.

2. Press

3. Enter the transmitter’s facility code (enter 0 if not used).
4. Press
5. Enter the transmitter’s ID number.
6. Press
7. Exit Programming Mode if all programming is complete.

Activate a Transmitter

If a transmitter has been suspended, it can be activated again with these
programming steps.

1. If not already in Programming Mode, connect by telephone or use the

local keypad. Enter the master password and access programming.

2. Press

3. Enter the transmitter’s facility code (enter 0 if not used).
4. Press
5. Enter the transmitter’s ID number.
6. Press
7. Exit Programming Mode if all programming is complete.

PPN 41

41#NUMBER#FC#ID#

NUMBER = NUMBER OF TRANSMITTERS IN THE BLOCK
FC = FACILITY CODE 0-15 (0 IF UNUSED)
ID = LOWEST TRANSMITTER ID NUMBER IN THE BLOCK

ASSIGN BLOCK TRANSMITTER

PPN 42

42#FC#ID#

FC = FACILITY CODE 0-15 (0 IF UNUSED)
ID = TRANSMITTER ID NUMBER

ACTIVATE A TRANSMITTER

PPN 43

43#FC#ID#

FC = FACILITY CODE 0-15 (0 IF UNUSED)
ID = TRANSMITTER ID NUMBER

SUSPEND A TRANSMITTER

PPN 45

45#FC#ID#

FC = FACILITY CODE (0 IF UNUSED)
ID = TRANSMITTER ID NUMBER

ASSIGN SINGLE ENROLLED TRANSMITTER

Advertising