2 functional, 3 physical – Orion Instruments Jupiter 2xx User Manual

Page 35

Advertising
background image

46-648 Jupiter Magnetostrictive Transmitters

35

2.7.2 Functional

Measured variables

Continuous liquid level

Input power (at terminals)

12-28 VDC

Signal output

Œ

4–20 mA

4–20 mA with HART 5.0

NAMUR NE 43 compliant with 3.8 to 21.5 mA useable range

Loop resistance

620 maximum ohms @ 24 VDC—refer to chart below

Power consumption

0.7 watt, refer to chart below

Damping

0 to 25 seconds

Error signal

3.6 or 22 mA, field selectable

User interface

3-button keypad, HART communicator, AMS software, PACTware

or F

OUNDATION

Fieldbus

Display

2-line

× 8-character LCD in inches or cm, mA, and % of level

Resolution

Analog:

0.01 mA

Digital:

0.01 units

Span

6 to 400 inches (999 cm)

SIL 2

Safe Failure Fraction (SFF) 90.7%
(consult factory for SIL safety manual)

1200

1000

800

600

400

200

0

0

10

20

30

40 VDC

20.5 mA

24 VDC

620

11

Power Consumption

Œ

See Bulletin 46-649 for
F

OUNDATION

Fieldbus output

Enclosure type

Dual compartment

Enclosure material

Sand cast aluminum grade 356 HT or 316 stainless steel

Enclosure finish

Baked on polymer powder coat

Enclosure rating

NEMA 4X7/9, IP 66

Sensor material

316 stainless steel

Sensor length

6 to 400 inches (15 to 999 centimeters)

2.7.3 Physical

Advertising