I/o menu descriptions, continued example, Idnone, The current id – Fairbanks 2800 Series Intrinsically Safe Instrument User Manual

Page 43: Enter, Id 3, 3, w, cr, Setpnt, 5806 (fiber optic cable), 2850 (safe area relay box), Setpnt modes

Advertising
background image

Section 3: Programming

01/12

43

50647 Rev. 9

3.5.1. I/O MENU DESCRIPTIONS, CONTINUED

EXAMPLE

The required ID is

3

(decimal equivalent is

51

).

1. Press the

ID

key.

─ Either

idnonE

or

the current ID

shows in the large display.

2. Using the numeric keypad, enter

51

.

3. Press

ENTER

.

─ When the PC sends

ID 3

, then a upper case

W

followed by a

C

carriage

return (

3, W, Cr

), the instrument with that ID responds with a data

transmission.

SEtPnt

The operation of Setpoint requires that accessories

5806 (Fiber Optic Cable)

and

2850 (Safe Area Relay Box)

be installed. There are five modes of setpoint

operation that may be selected from during the installation and programming by your
local Fairbanks Service Center or Authorized Factory trained Distributor.

SEtPnt Modes

PROMPT

CHOICE(S)

SPCont

 Continuous operation of setpoints, ON at entered target weight.
MUST press

START

to begin function.

SPChEC

 Check weighing, such as UNDER/ACCEPT/OVER, with setpoint

Relays 1 and 2 active for alarms.

SPALrt

 Setpoint Relay 8 is active, used as both LOW and HIGH alarms in

SoLo

mode

.

 Or Relays 4 and 8 if in

Paired

mode.

SPAUto

 Automatic batching, a range of materials can be added one at a time to

complete a batch.

SPAUto

will not function

when in the Gallons mode.

 When

configuring

SdELAY

, to perform the delay in minutes and

seconds between ingredients, the setting is located in the main I/O
Menu.

SPhAnd

This operation requires a manual

START

at each setpoint.