Appendix IV: Continuous Output Data Streams

A. FORMAT: FAIRBANKS COMPUTER (FBPUTR)

Character

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Data String

STX A B C x x x x x x t t t t t t CR


x

= Displayed weight; Gross or Net

t

= Tare Weight

A

= Status Word A

B

= Status Word B

C

= Status Word C

Leading zeros are suppressed.

The following tables define the value of Status Word A, B, and C:

A.1. STATUS WORD A

DIVISION SIZE

DECIMAL POINT OR ZERO LOCATION

BIT NO.

X0

X

0.X

0.0X

0.00X

0.000X

0.0000X

0 1 0 1 0 1 0 1
1

0

1

1

0

0

1

1

2 0 0 0 1 1 1 1

BIT NO.

COUNT BY 1

COUNT BY 2

COUNT BY 5

3

1 0

1

4

0

1

1

5

Always

Logic

1

6

Always Logic 0

7

Parity

Bit

Advertising