C. format: weightronix (tronix) – Fairbanks 2800 Series Intrinsically Safe Instrument User Manual

Page 67

Advertising
background image

Appendix IV: Continuous Output Data Streams

01/12

67

50647 Rev. 9

C. FORMAT: WEIGHTRONIX (TRONIX)

Character

1 2 3 4 5 6 7 8 9 10 11 12 13

Data String

L L x x x x x x sp U U CR LF


Variable data string length using gallon units.

Character

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Data String

L L x x x x x x sp U U U* CR LF


Variable length using lb/oz units

Character 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16
Data String L L x x x x x x sp U U U* U* U* CR
LF


L

= legend

spG = Gross

0N

= Net

x = weight

sp

= space

U

=

Units selected

U* =

Units selected; these are optional characters which will appear based upon the units

displayed. The data string length will vary if these units are selected.

lb

= pounds

kg

= kilograms

oz

= ounces

g

= grams

tn

= tons

gal*

= gallons

lb/oz*

= pounds-ounces

Leading zeros are suppressed.

In a Underload or Overload condition the weight data and legends are
suppressed.

The first character for a gross data string is a space.

Advertising