A. format: fairbanks computer (fbputr), continued, B. 4. format : consolidated controls (concon) – Fairbanks 2800 Series Intrinsically Safe Instrument User Manual

Page 66

Advertising
background image

Appendix IV: Continuous Output Data Streams

01/12

66

50647 Rev. 9

A. FORMAT: FAIRBANKS COMPUTER (FBPUTR), CONTINUED

Character

1 2 3 4 5 6 7 8 9 10

Data String

STX 4 y x x x x x x ETX


x

= weight

y

= Second digit of a id code i.e. 4y where y= 0, 1, 3, or 4.

40

= Gross lb, oz, lb-oz, ton, or gallons

41

= Net lb, oz, lb-oz, or ton

43

= Gross kg or grams

44

= Net kg, grams, or gallons

Underload condition data stops transmitting.

Overload condition data is transmitted as the id followed by dashes.

Leading zeros are suppressed.

B. 4. FORMAT : CONSOLIDATED CONTROLS (CONCON)

Character

1 2 3 4 5 6 7 8 9 10

Data String

STX x x x x x x U E CR


x

= Displayed weight; Gross or Net

U

= Units selected

L

= pounds

K

= kilograms

O

= ounces

G = grams

T

= tons or gallons

E

= Error flag

M

= motion

O

= underload or overload

Space

= no errors

Leading zeros are suppressed.

In a Underload or Overload condition the weight data is suppressed.