: Demand Output Data Streams

A. FORMAT : COMPUTER POLLED (POLL)

Character 1 2 3 4 5 6 7 8 9 10 11 12 13
Data String sp x x x x x x sp U U sp L L

x

= weight

sp

= space

U

= Units selected

LB

= pounds

KG

= kilograms

OZ

= ounces

GM

= grams

TN

= tons

GM

= gallons

LB

= pounds-ounces

L

= legend

GR

= Gross

NT

= Net

Leading zeros are suppressed.

In a Motion condition, the legend will change to lower case.

In a underload or overload condition, the unit will transmit

a --uL-- or a --oL—

Polling request is a capital W followed by a carriage return.