Mk series – General Pump MK Repair Manual User Manual

Page 13

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

MK SERIES

To separate the rod from the plunger guide, unfasten the M10 hexagonal-head screws using a size 17 socket

wrench (1, fig. 37).

2.1.2 Crank Mechanism Assembly

Proceed with assembly by inverting the precedure indicated in paragraph 2.1.1.

The correct sequence is the following:

Connect the rod to the plunger guide

Insert the Ø5 pin in the appropriate hole on the plunger guide (1, fig. 38) and connect the rod to the plunger

guide using M10 x 35 screws (1, fig. 39).