GENERAL PUMP

A member of the Interpump Group

MK SERIES

Insert the shaft (1, fig. 29) until the pre-assembled bearing is aligned with the edge of the crankcase

(1, fig. 43).

Manually insert the pressure sleeve to maintain the shaft alignment (1, fig. 44).

Assemble the reducer case (1, fig. 45) and the related gasket (2, fig 45) using the 6 M12 x 40 screws

(1, fig. 46), the 2 M12 x 50 screws (1, fig. 47) and the Ø 12 Grower washers (2, fig. 46 and fig. 47).

Calibrate the screws with a torque wrench (1, fig. 48) as indicated in paragraph 3. “SCREW CALIBRATION”