Page 32

Assemble the head on the pump casing (1, fig. 107) being careful not to bump against the plungers, and

fasten the 8 M16 x 180 screws (1, fig. 108).

Proceed with calibrating the M16 by 180 screws with the torque wrench as indicated in paragraph 3.

“SCREW CALIBRATION”

Fasten the 8 M16 x 180 screws starting from the 4 internal screws cross-wise (see fig.

107), and then proceed with the 4 external screws, again fastening cross-wise.

Calibrate the M16 x 55 cover screws with the torque wrench as indicated in paragraph 3. “SCREW

CALIBRATION”

Apply the valve opening devices (1, fig. 109) and fasten them using a 30 mm wrench (1, fig. 110).