Mk series – General Pump MK Repair Manual User Manual

Page 37

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

MK SERIES

Replace the pressure packings by applying a small amount of silicone grease to the

lips, being careful not to damage them when inserting the liner.

At each disassembly, the pressure packings must always be replaced together with all

the O-rings.

Insert the low pressure packings in the packing support (1, fig 124), being careful that the sealing lips are

facing frontwards (toward the head).

Assemble the head ring (1, fig. 125), the high pressure packing (1, fig. 126) and the restop ring

(1, fig. 127).

Page 37

Couple the packing support to the liner (1, fig. 128).

2.2.4 Assembly of the Plunger Unit - Support - Seals

Proceed with reassembly by inverting the disassembly procedure indicated in paragraph 2.2.3.

Advertising