Insert the anti-extrusion ring, exploded view item 16 in Owner’s Manual (1, fig. 99).

Pay particular attention when inserting the O-ring indicated in 1, fig. 101. We advise

to use the correct tool p/n 27516000 (for MK40A, MK45A and MK50A) or p/n 27516100

(for MK55A, MK60A and MK65A) in order to avoid cutting the O-ring during insertion.

Insert the O-ring, exploded view item 17 in Owner’s Manual, (1, fig. 100).