Mk series – General Pump MK Repair Manual User Manual

Page 5

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

MK SERIES

Page 5

Unfasten the reducer cover screws (1, fig. 6).

Insert 3 dowels, or 3 M8 threaded screws (1, fig. 7) in the appropriate holes to aid extraction, and two

sufficiently long M10 screws in order to support the cover (2, fig. 7).

Disassemble the crankcase cover by unfastening the relevant screws (1, fig. 5).

Advertising