8

Manual Tank Fill

1. After the vacuum pump shuts off, the unit

displays,

CONNECT SOURCE TANK TO

TANK FILL HOSE, OPEN TANK VALVE,

AND ORIENTATE TANK

TO PROVIDE LIQUID SUPPLY.

PRESS START TO BEGIN OR EXIT TO ABORT.

Connect the fill hose to the liquid connector on a

full source tank. See Figure 5.

2. Open the source tank valve.
3. Install the source tank, and secure it to the unit

(using the tank strap) in such a way that liquid
refrigerant is supplied to the connection.

Figure 5

Side View

Fill Hose

(connect to

liquid line)

Source

Tank

Strap

CAUTION: The vacuum pump is shipped

without oil in the reservoir . Failure to add oil

will damage the vacuum pump .

2. Remove the plug from the vacuum pump oil fill

port.

3. Attach the flexible tube/cap to the oil bottle (from

the accessory kit); pour only five (5) ounces
of vacuum pump oil into the fill port. Note: You
will top off the oil in the next step as the vacuum
pump is running.

4. Select NEXT. While the vacuum pump is

running, slowly add oil until the level rises to the
center of the sight glass.

5. Install the plug in the fill port, and select EXIT.

The unit pulls a 3-minute vacuum to clear all
internal air before proceeding.

Note: The “burping” noise heard during this
process indicates air is being purged from the
system—this is normal.

CAUTION: The unit is programmed

to run the setup procedure as outlined
here . To prevent personal injury, do
NOT operate the unit at any other
time without the oil fill port plug
installed, because the vacuum pump is
pressurized during normal operation .

Maintain Vacuum Pump contd .

Setup