23

554228 Rev. E July 30, 2013

Maintenance

Change Vacuum Pump Oil

For maximum vacuum pump performance, change

the vacuum pump oil after every 10 hours of

operation.
1. Select SETUP MENU. Scroll to MAINTAIN

VACUUM PUMP and select START.

The display shows how long the vacuum pump

has operated since the last oil change and

the amount of time remaining until the next oil

change is needed:

VACUUM OIL TIME: XX:XX

OIL LIFE REMAINING: XX:XX

CHANGE VACUUM PUMP OIL NOW?

SELECT YES TO CHANGE OIL OR NO TO EXIT

2. Select YES. The display shows

WARMING OIL FOR BETTER DRAIN.

VACUUM TIME: XX:XX

Allow the vacuum pump to run until it

automatically stops. This will take approximately

one minute.

3. The display then shows

DRAIN USED OIL AND ADD 5 OZ OF NEW OIL.

PRESS NEXT TO CONTINUE OR EXIT TO ABORT.
Refer to Figure 15, and remove the plug from

the oil fill port. (The pump drains faster when

vented.)

4. Remove the oil drain fitting cap, and drain the oil

into a suitable container for disposal. Replace

the cap.

5. Attach the flexible tube/cap to the oil bottle (from

the accessory kit). Pour only five (5) ounces

of vacuum pump oil into the fill port. Note: You

will top off the oil in the next step as the vacuum

pump is running.

6. Select NEXT. The unit displays

FILL VACUUM PUMP WITH NEW OIL UNTIL

THE LEVEL REACHES THE MIDDLE OF THE

SIGHT GLASS.

REPLACE CAP AND PRESS EXIT WHEN

COMPLETE.

While the vacuum pump is running, slowly add

oil until the level rises to the center of the sight

glass.

7. Install the plug in the fill port, and select EXIT.

Review the laws in your jurisdiction
to determine the correct disposal
procedure for pump oil . It is the
responsibility of the user to determine
if a material is a hazardous waste at
the time of disposal. Ensure you are
in compliance with all applicable laws
and regulations .

Oil Drain Fitting

Oil Fill

Port

Sight Glass

Figure 15

CAUTION: To prevent personal

injury, do NOT operate the unit at
any time without the oil fill port
plug installed, because the vacuum
pump is pressurized during normal
operation .