Maintenance

General Maintenance

1. On a regular basis, wipe off the unit using a

clean cloth to remove grease and dirt.

2. Periodically check internal components for

leaks; over time, fittings can loosen as the unit

is moved. Open the door panel, and trace lines

using a leak detector. Check connections on

the back of the unit. Tighten any loose fittings or

connections you may find.

Electrical Protection

The unit is equipped with a 15 amp circuit breaker

on the back panel. See Figure 9. If the breaker

trips, its button will pop out. A tripped circuit

breaker will cause the unit to lose all power.
Press the circuit breaker button to reset.

Manually Fill the
Internal Storage Vessel (ISV)

This menu item is used to transfer refrigerant from

a source tank to the internal storage vessel.
Note: If a refrigerant source tank remains

connected to the unit during normal operation, the

correct amount of refrigerant will automatically be

maintained in the ISV. The ISV may be manually

refilled, if necessary.

1. Select SETUP MENU. Scroll to TANK FILL and

select START. The unit displays

CONNECT SOURCE TANK TO

TANK FILL HOSE, OPEN TANK VALVE, AND

ORIENTATE TANK TO PROVIDE LIQUID

SUPPLY. PRESS START TO BEGIN OR EXIT TO

ABORT.

2. Connect the fill hose to the liquid connector on

a full source tank, and open the source tank

valve. See Figure 10.

3. Install the source tank, and secure it to the unit

(using the tank strap) in such a way that liquid

refrigerant is supplied to the connection.

4. Press START to begin filling the ISV.
5. The unit automatically stops when the preset

tank fill level is reached. To stop the tank fill

before the preset level is reached, select

PAUSE and EXIT.

Figure 10

Side View

Fill Hose

Source

Tank

Strap

Circuit

Breaker

Figure 9

Back View

MAIN POWER

BREAKER

Note: Only the amount of refrigerant
available for charging is displayed. For
example, if the tank fill default is set at
15 lbs., the unit will transfer 15 lbs. to
the ISV, but the display may show only
13 lbs.