Select Units

The operator may choose to have units of measure
displayed in pounds, kilograms, ounces, or grams.
1. Use the UP or DOWN arrow key or select

TOGGLE UNITS to toggle through the choices.

2. Select SAVE to choose the displayed unit of

measure.

Set Date and Time

The machine is programmed at the factory for the
local time zone and date. Use the keypad and
arrow keys to revise that information.
1. Use the keypad to enter the date and time.

Press “2” for AM; press “7” for PM.

2. Select SAVE to accept the date and time.

Adjust Tank Fill Default

The operator may either accept the unit’s pre-set
default weight of 15 lbs. of refrigerant stored in the
internal storage vessel (ISV), or change the amount
to accommodate the application. The unit displays

15.00 LBS.

ENTER THE AMOUNT OF REFRIGERANT THAT

THE TANK FILL FUNCTION SHOULD MAINTAIN

IN THE INTERNAL STORAGE VESSEL.

MAX = 17.00LB MIN = 04.00LB

SELECT SAVE TO ACCEPT OR EXIT TO ABORT

1. Select SAVE to accept the default amount, or use

the keypad to enter an amount and select SAVE.

Maintain Vacuum Pump

Note: Service hoses are shipped in the accessory kit.
The unit displays

INSTALL SERVICE HOSES ONTO BULKHEADS

AND STORAGE PORTS.

ADD 5 OZ OF NEW OIL TO VACUUM PUMP.

PRESS NEXT TO CONTINUE OR EXIT TO

ABORT.

1. Connect the service hoses from the bulkhead

fittings (located on the side of the unit) to the
storage ports. See Figure 4. Connect the red
hose to the fitting labeled HIGH; connect the
blue hose to the fitting labeled LOW.

Figure 4
Side View

Hose

Bulkheads

Hose Storage

Ports

Oil Fill Port

Vacuum Pump

Sight

Glass

Setup

CAUTION: R-134a systems have special
fittings (per SAE specifications) to avoid
cross-contamination with other systems .
DO NOT adapt your unit for a different
refrigerant — system failure will result .