Maintenance

Inspect the unit periodically for
leaks . The manufacturer does not
reimburse for lost refrigerant .

Adjust Tank Fill Level

When connected to a refrigerant source, the unit
maintains a default value of 15 lbs. of refrigerant
in the internal storage vessel. This value may be
adjusted up or down to suit the application. The
minimum value is 4 lbs.; the maximum value is
17 lbs.
1. Select SETUP MENU. Scroll to ADJUST

REFILL DEFAULT and select START.

2. The unit displays

15.00 LBS.

ENTER THE AMOUNT OF REFRIGERANT THAT

THE TANK FILL FUNCTION SHOULD MAINTAIN

IN THE INTERNAL STORAGE VESSEL.

MAX = 17.00LB MIN = 04.00LB

SELECT SAVE TO ACCEPT OR EXIT TO ABORT.

3. Select SAVE to accept the default amount, or

use the keypad to enter an amount and select
SAVE.

Check for Leaks

Check the unit for leaks every three months, or as
specified by law in your jurisdiction.
1. Turn off the main power switch, and disconnect

the power cord from the outlet.

2. Open the rear door. Remove the top cover and

the front panel.

3. Use a leak detector to probe all connections

for refrigerant leaks. Tighten fittings if a leak is
indicated.

4. Reassemble the body panels, and close the rear

door.

Replace the Printer Paper

1. Press the oval button at the top of the printer to

release the printer cover. See Figure 16.

2. Grasp the tabs and pull the cover off the printer.
3. Remove the paper core.
4. Install the new roll of paper with the end of the

paper at the top of the roll.

5. Assemble the cover onto the printer with the end

of the paper over the roller.

Oval Button

Tab

Tab

Paper Feed

Figure 16