Operating Instructions

Recharge the A/C System contd .

7. When the charge is complete, the display shows

CHARGE DIAGNOSTICS

HIGH SIDE XX PSI MAX XX PSI

LOW SIDE XX PSI MIN XX PSI

CHARGE AMOUNT: XX.XX LBS

START A/C TO PERFORM DIAGNOSTICS OR

WITH A/C OFF, PRESS NEXT TO CLEAR

HOSES.

To obtain current pressure readings and

diagnostics from the vehicle, start the vehicle's
air conditioning system (set at maximum output),
or select NEXT to continue.

8. The unit displays

CHARGE COMPLETE

SELECT EQUALIZE TO USE A/C SYSTEM

TO CLEAR HOSES.

SELECT COMPENSATE TO USE HOSE

COMPENSATION AND NOT RUN A/C SYSTEM.

Select EQUALIZE to ensure all liquid refrigerant

trapped in the hoses is transferred to the vehicle
A/C system for an accurate charge.

OR

Select COMPENSATE to charge a small

amount of refrigerant into the vehicle A/C
system to offset any refrigerant that may be left
in the hoses.

WARNING: To prevent personal injury,

Verify the vehicle is in park or neutral

with the emergency brake ON before
starting the engine .

Never run a vehicle without adequate

ventilation in the work area .