Parameters, 1 parameter table – IAI America ACON-CG User Manual

Page 136

Advertising
background image

122

8. Parameters

8. Parameters

8.1 Parameter

Table

Category:

a: Parameter relating to the actuator stroke range
b: Parameter relating to the actuator operating characteristics
c: Parameter relating to the external interface
d: Servo gain adjustment

No. Category Symbol

Name Unit

Default

factory

setting

1

a

ZONM Zone boundary 1+

mm

Effective actuator length

2

a

ZONL Zone boundary 1–

mm

Effective actuator length

3

a

LIMM Soft limit+

mm

Effective actuator length

4

a

LIML

Soft limit–

mm

Effective actuator length

5 a ORG

Home return direction
[0: Reverse / 1: Forward]

-

(In accordance with the specification at the
time of order)

6

b

PSWT Push & hold stop judgment period

msec

255

7

d

PLG0 Servo gain number

-

Set individually in accordance with the
actuator characteristics.

8 b

VCMD

Default

speed

mm/sec

Set individually in accordance with the
actuator characteristics.

9 b

ACMD

Default

acceleration/deceleration

G

Set individually in accordance with the
actuator characteristics.

10

b

INP

Default positioning band (in-position)

mm

0.10

13

b

ODPW Current-limiting value during home return

%

Set individually in accordance with the
actuator characteristics.

15 c FPIO

Pause input disable selection
[0: Enable / 1: Disable]

-

0 [Enable]

16

c

BRSL SIO communication speed

bps

38400

17 c RTIM

Minimum delay time for slave transmitter
activation

msec

5

21 c FPIO

Servo ON input disable selection
[0: Enable / 1: Disable]

-

0 [Enable]

22

a

OFST Home return offset

mm

Set individually in accordance with the
actuator characteristics.

23

a

ZNM2 Zone boundary 2+

mm

Effective actuator length

24

a

ANL2 Zone boundary 2–

mm

Effective actuator length

25

c

IOPN PIO pattern selection

-

0 [Positioning mode (standard type)]

26

b

IOJV

PIO jog speed

mm/sec

100

27 c FPIO

Movement command type
[0: Level / 1: Edge]

- 0

[Level]

28 b PHSP

Default direction of excited-phase signal
detection [0: Reverse / 1: Forward]

-

Set individually in accordance with the
actuator characteristics.

29

b

PHSP Excited-phase signal detection time

msec

Set individually in accordance with the
actuator characteristics.

30 b PHSP

Pole sensing type [0: Current
suppression / 1: Distance suppression]

-

1 [Distance suppression]

31

d

VLPG Speed loop proportional gain

-

Set individually in accordance with the
actuator characteristics.

32

d

VLPT Speed loop integral gain

-

Set individually in accordance with the
actuator characteristics.

33

d

TRQF Torque filter time constant

-

Set individually in accordance with the
actuator characteristics.

34 b PSHV

Push

speed

mm/sec

Set individually in accordance with the
actuator characteristics.

35 b SAFV

Safety

speed

mm/sec

100

36

b

ASO1 Automatic servo-off delay time 1

sec

0

37

b

ASO2 Automatic servo-off delay time 2

sec

0

38

b

ASO3 Automatic servo-off delay time 3

sec

0

39 c FPIO

Output mode of position complete signal
[0: PEND / 1: INP]

- 0

[PEND]

40 c HOME

Home-return input disable selection [0:
Enable / 1: Disable]

-

0 [Enable]

Advertising
This manual is related to the following products: