24

4. W

iring

Red

White

Black

Controller

Connected to teaching
pendant or PC

External EMG switch

Input power
supply
24 VDC

I/O flat cable

Terminal block

Actuator

Motor

Encoder

Holding brake

Brake release switch

Tighten together with the
mounting screw.

0 V (NPN specification)
24 V (PNP specification)

24 V (NPN specification)
0 V (PNP specification)

24-VDC power for
input/output signals

‚

For details on I/O signal connection,

refer to 4.3, “Connecting the I/O
Cables.”

‚

Refer to the operation manual of each
network and the operation manual of
the PLC master unit for how to wire
communication cables of the network
connection specifications.

Load

Load

Connection

detection circuit

Inpu

t

Outp

ut

Motor relay cable

Encoder extension
cable

Blue

Orange

Gray

Red

Black

Yellow

Pink

Purple

Orange/White

Green/White

Blue/Red

Brown

Green

Home check

sensor

4. Wiring

4.1 Positioner Type (with Internal Drive-power Cutoff Relay) (ACON-C)

4.1.1 External

Connection

Diagram

An example of standard wiring is shown below.
(Note) The encoder cable shown in the example is the standard cable for the controller with the

maximum current of 2 A.
As for the robot cable or the cable for the dedicated controller for the high-thrust type, refer to
4.4.2, “Encoder Extension Cable.”