Dryer control panel – Airstream 1100 SERIES SINGLE FAN PNEG-339 User Manual

Page 11

Advertising
background image

11

DRYER CONTROL PANEL

SETTING THE DRY (16),

COOL (17) AND UNLOAD

(18) BATCH TIMERS

ELECTRONIC

MONITORING CONTROL

SYSTEM (14)

Figure 2: The Airtream Electronic Monitoring Control System

These switches are used to set the

cycle times in the STAGED BATCH

DRYING MODE only. The DRYING

MODE switch must be in the

STAGED BATCH position. The cur-

rent settings on these three TIMERS

are displayed directly above each

TIMER button. To change the set-

ting of these TIMERS follow these

instructions:

1.

Press the DRY, COOL or UN-

LOAD TIMER button.

2.

Press the MODIFY button.

3.

Press the INCREASE or DE-

CREASE button to adjust the

settings.

4.

Press the ENTER button.

During operation the remaining

time on each TIMER is displayed on

the screen. If the power goes out or

If the dryer runs out of grain while

the LOAD AUGER switch is in the

AUTO position, the OUT OF GRAIN

TIMER automatically shuts OFF the

dryer after the period of time preset

on the TIMER. When pressed, the

display will show the amount of time

left on the TIMER and the percent-

age of time the last load expended.

A second screen will appear show-

ing the TIMER'S setting and will al-

low the operator to modify it as de-

scribed for setting the BATCH TIM-

ERS.

SETTING THE OUT OF

GRAIN TIMER (19)

Turn the CONTROL POWER switch

to ON. The monitor will display a

copyright message and model num-

ber, total running time in hours and

minutes and the current time and

date. To activate the controller press

the RESET button.

TURNING ON THE

ELECTRONIC

MONITORING CONTROL

SYSTEM USING THE
RESET BUTTON (15)

The Electronic Monitoring Control

System (Figure 2) controls all tim-

ing functions and safety circuit

checks. It is designed to simplify

dryer operation by providing printed

messages and warnings on its liq-

uid crystal display (LCD).

if the dryer is stopped, these times

are saved by the controller. When

the dryer is restarted the TIMERS

will continue timing down. The TIM-

ERS will return to their initial settings

by pressing the RESET button.

Advertising