Service how to determine a metering roll problem, How to clear a jammed metering roll – Airstream 1100 SERIES SINGLE FAN PNEG-339 User Manual

Page 35

Advertising
background image

35

SERVICE

HOW TO DETERMINE A METERING ROLL PROBLEM

To determine if the metering prob-

lem is from blockage, perform the

following test with the power off.

Remove the drive chain by loosen-

ing the motor mounting bolts. Refer

to photo, and place a pipe wrench

on the hub of the roller chain

sprocket, on the left hand metering

roll at the drive end of the dryer.

Apply up to 100 ft. lbs. of force, and

attempt to rotate the roll toward the

inside of the dryer. If the metering

roll will turn, then repeat for right

hand side. If metering roll will turn,

it can be assumed that no blockage

exists, and the problem is from some

other cause. Check for a break in

the power train, chain, drive key, pin,

etc.

CAUTION: Keep hands away from

sprocket teeth to avoid injury

from chain backlash, as a result

of torsion build up in the system

caused by the jam.

The auger discharge switch.

SERVICE TOOL

The metering roll drive.

HOW TO CLEAR A JAMMED METERING ROLL

This column cutoff damper is designed to insert through the grain column

(from the inside of the dryer) immediately above the metering roll. This

permits opening of the metering roll access door. For service or inspec-

tion without unloading the dryer, the plenum bottom closure panel and

metering roll adjust damper must be removed prior to using service tool.

noise when making this check. Once

the location is determined, the roll can

be reached from the outside by open-

ing the access door to remove the for-

eign object causing the jam (before

opening doors see below). The ser-

vice tool must be inserted before open-

ing doors. First, swing open the ple-

num bottom closure panel. Insert

service tool above metering roll.

Place a pipe wrench on the hub of

the sprocket of the jammed meter-

ing roll and turn the roll. First back-

ward, and then forward several times

in an attempt to dislodge the object,

and clear it through the roll. If this is

not successful, have an assistant

turn the metering roll, and attempt to

locate the jam by sound. Shut down

the fan heater and eliminate any other