DRYER PRE START CHECKS

STAGED BATCH CHECK

DRYER SHUTDOWN

To shutdown the dryer, first CLOSE

the FUEL SUPPLY VALVE at the

tank or valve along the fuel line. If

the burner is operating, let the dryer

run out of fuel, and it will shutdown

automatically due to loss of flame.

CLOSE the FUEL VALVE at the

dryer, and press the DRYER

POWER STOP button. Turn OFF

the safety disconnect handle on

the front of the power box, and turn

OFF the main POWER to the dryer.

In case of emergency push the dryer

POWER STOP button. The fan,

burner and all augers will stop im-

mediately.

EMERGENCY

VALVE to allow fuel flow to the

dryer, if so equipped. Turn the

LOAD switch to AUTO and UN-

LOAD switch to 1 SPEED. Push

the DRYER POWER START but-

ton and the controller will sequen-

tially start all dryer components in

their proper order. If any switches

are not in their correct position for

staged batch operation, the dryer

will indicate improper switch posi-

tion, and will not start until the

switches are in the proper position.

After starting, all batch timers will

time down in sequence. When the

unload cycle is complete the tim-

ers will automatically reset to their

original settings, and start the dry

timer again.

To check the staged batch opera-

tion, turn the CONTROL POWER

switch to the ON position. Press the

RESET button, OPEN the main

FUEL SUPPLY VALVE at the tank

on an LP dryer or valve in the fuel

supply line on a natural gas dryer.

Turn the DRYING MODE switch to

the STAGED BATCH position.Turn

ON the electric SHUT OFF

pressure with the LOW-FIRE CON-

TROL VALVE. If the gas pressure

is decreased too much a popping or

fluttering sound will be heard. Also,

anytime the high pressure side is

adjusted the low pressure side

needs to be checked.

All dryer functions should be checked before operation each season.