DRYER CONTROL PANEL

FAN SWITCH (7)

This is used to select the opera-

tion of the load auger. In both the

AUTO and MANUAL position the

load auger will operate if the dryer

is low on grain, and will automati-

cally shut off when the dryer is full.

In the AUTO position only, the

dryer will shut down after a prede-

termined period of time set on the

OUT OF GRAIN TIMER, or if grain

flow is interrupted to the dryer. The

switch will light whenever the load

auger is operating.

Note: When this switch is set

to AUTO or MANUAL it also con-

trols the operation of any auxiliary

load equipment being utilized,

such as an auxiliary auger or con-

veyor.

LOAD AUGER SWITCH (6)

This is used to select STAGED

BATCH or CONTINUOUS FLOW

drying. The switch will light only af-

ter the Electronic Monitoring Con-

trol System has been turned ON,

the safety circuit is okay and the

RESET button has been pressed.

DRYING MODE SWITCH (5)

HEATER SWITCH (8)

UNLOAD SWITCH (9)

The UNLOAD switch turns the me-

tering rolls and discharge auger

ON or OFF, and selects the opera-

tion of the metering rolls.

• In the 2 SPEED position if the

MOISTURE CONTROL switch is

ON, and the DRYING MODE

switch is turned to CONTINUOUS

FLOW, the METERING ROLL

SPEED will alternate between the

HIGH speed metering roll potenti-

ometer setting and the LOW

speed metering roll potentiometer

setting depending on the control

signal from the MOISTURE CON-

TROL THERMOSTAT. The dis-

charge auger will operate con-

tinuously.

• In the 1 SPEED position, if the

MOISTURE CONTROL switch is

ON, and the DRYING MODE

switch is turned to CONTINUOUS

FLOW, the METERING ROLL

SPEED will operate at the HIGH

speed metering roll potentiometer

setting or turn OFF depending on

the control signal from the MOIS-

TURE CONTROL THERMO-

STAT. The discharge auger will

operate whenever the metering

rolls are operating.

• In both the 1 SPEED or the 2

SPEED position, if the MOIS-

TURE CONTROL THERMOSTAT

is OFF, and the DRYING MODE

switch is turned to CONTINUOUS

FLOW, the METERING ROLL

SPEED can be manually con-

trolled by adjusting the HIGH

speed metering roll potentiometer.

The discharge auger will operate

continuously.

• If the DRYING MODE switch is

turned to STAGED BATCH, the

UNLOAD switch should be set to

the 1 SPEED position. The dis-

charge auger and metering rolls

will only operate during the unload

cycle of the staged batch opera-

tion, and the METERING ROLL

SPEED is adjusted using the

HIGH speed metering roll potenti-

ometer.

Note: When this switch is set to

AUTO or MANUAL it also controls

the operation of any auxiliary load

equipment being utilized, such as

an auxiliary auger or conveyor.

The fan is turned ON or OFF with

this switch. The ON position oper-

ates the fan continuously during

STAGED BATCH and CONTINU-

OUS FLOW modes. The AUTO po-

sition operates the fan in STAGED

BATCH during the dry and cool

cycle. The switch will light up when-

ever the airflow switch is sensing

airflow and the dryer is full of grain.

The power to the Electronic Moni-

toring Control System is turned

ON or OFF with this switch.

The dryer service light is turned

ON or OFF here. It also may be

set on AUTO, which turns the light

on while the dryer is running, and

off if a shutdown occurs.

This switch is used to turn the

burner ON or OFF. The AUTO po-

sition operates the burner in

STAGED BATCH during the dry

cycle. The ON position will operate

the burner only when the fan is run-

ning. The switch will light up when

the flame sensor detects the flame.

OUTSIDE LIGHT (4)

CONTROL POWER

SWITCH (3)

Advertising